{"id":1413,"date":"2026-11-10T10:20:51","date_gmt":"2026-11-10T10:20:51","guid":{"rendered":"https:\/\/www.astor.com.pl\/en\/?p=1413"},"modified":"2026-11-10T10:20:51","modified_gmt":"2026-11-10T10:20:51","slug":"configuring-an-external-e-stop-signal-in-corecubic-s","status":"publish","type":"post","link":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/","title":{"rendered":"Configuring an External E-STOP Signal in CoreCubic-S"},"content":{"rendered":"<h2 aria-level=\"2\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1415\" src=\"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head.jpg\" alt=\"\" width=\"900\" height=\"400\" srcset=\"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head.jpg 900w, https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head-300x133.jpg 300w, https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head-768x341.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/h2>\n<h2 aria-level=\"2\"><span data-contrast=\"none\">What Is E-STOP?<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h2>\n<p><span data-contrast=\"auto\"><strong>E-STOP<\/strong> (emergency stop) is one of the fundamental safety functions used in industrial robotic cells. It enables the robot or other devices within the system to be stopped in an emergency, for example, when an external emergency stop button is pressed.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The CoreCubic-S system allows an external safety signal to be assigned to the robot\u2019s emergency stop function. A safety output can also be configured to forward information to a higher-level device, such as a Safety PLC, confirming that the motor power shutoff command has been executed.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:279}\">\u00a0<\/span><\/p>\n<h2 aria-level=\"2\"><span data-contrast=\"none\">Configuration Scope<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h2>\n<p><span data-contrast=\"auto\">The configuration described in this article includes:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<ol>\n<li><span data-contrast=\"auto\">Assigning User Safety Input 1 to the external emergency stop function.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<li><span data-contrast=\"auto\">Configuring User Safety Output 1 as a status signal indicating that the motor power shutoff command has been executed.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/li>\n<\/ol>\n<p><span data-contrast=\"auto\">An additional Safety I\/O board is required to support the safety inputs and outputs.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h2 aria-level=\"2\"><span data-contrast=\"none\">Configuring E-STOP using the Teach Pendant<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h2>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Adding a Safety I\/O Board<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">Adding a Safety I\/O board enables the usage of safety inputs and outputs in the CoreCubic-S system. The value specified in the configuration must correspond to the number of Safety I\/O boards physically installed in the controller.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Go to menu:<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">TEACH \u2192 CCS (Core Cubic-S) \u2192 Status \u2192 System<\/span><\/b><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<figure id=\"attachment_1414\" aria-describedby=\"caption-attachment-1414\" style=\"width: 694px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1414 size-full\" style=\"font-size: 1rem;\" src=\"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/01-2.jpg\" alt=\"\" width=\"694\" height=\"410\" srcset=\"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/01-2.jpg 694w, https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/01-2-300x177.jpg 300w\" sizes=\"auto, (max-width: 694px) 100vw, 694px\" \/><figcaption id=\"caption-attachment-1414\" class=\"wp-caption-text\">Fig. 1. Setting the number of Safety I\/O boards.<\/figcaption><\/figure>\n<p><span data-contrast=\"auto\">In the <\/span><b><span data-contrast=\"auto\">Safety I\/O Boards<\/span><\/b><span data-contrast=\"auto\"> field, set the value to: <\/span><b><span data-contrast=\"auto\">1.<\/span><\/b> Cofirm the configuration by clicking the &#8220;Update&#8221; button.<\/p>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Assigning an Input to the E-STOP Function<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">Assigning the safety input enables the signal from <\/span><b><span data-contrast=\"auto\">User Safety Input 1<\/span><\/b><span data-contrast=\"auto\"> to be used as an external emergency stop signal.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Go to menu:<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">Signal Settings \u2192 Logical Operation<\/span><\/b><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">In the <\/span><b><span data-contrast=\"auto\">LogicOP Result No.<\/span><\/b><span data-contrast=\"auto\"> field, enter: <\/span><b><span data-contrast=\"auto\">1<\/span><\/b><span data-contrast=\"auto\">.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Then configure the first logical operation:<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">OP:<\/span><\/b><span data-contrast=\"auto\"> Thru<\/span><br \/>\n<b><span data-contrast=\"auto\">IN1:<\/span><\/b><span data-contrast=\"auto\"> User Safety Input (1)<\/span><br \/>\n<b><span data-contrast=\"auto\">Assign:<\/span><\/b><span data-contrast=\"auto\"> SW External Emergency Stop<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<figure id=\"attachment_1417\" aria-describedby=\"caption-attachment-1417\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-1417\" src=\"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/02-2-1024x578.jpg\" alt=\"\" width=\"1024\" height=\"578\" srcset=\"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/02-2-1024x578.jpg 1024w, https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/02-2-300x169.jpg 300w, https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/02-2-768x433.jpg 768w, https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/02-2.jpg 1074w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption id=\"caption-attachment-1417\" class=\"wp-caption-text\">Fig. 2. Configuring the input assignment for the E-STOP function.<\/figcaption><\/figure>\n<p><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:2,&quot;335551620&quot;:2,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><span data-contrast=\"auto\">The <\/span><b><span data-contrast=\"auto\">Thru<\/span><\/b><span data-contrast=\"auto\"> operation transfers the state of the specified input without performing any additional logical operations. In this configuration, the state of <\/span><b><span data-contrast=\"auto\">User Safety Input 1<\/span><\/b><span data-contrast=\"auto\"> is assigned directly to the <\/span><b><span data-contrast=\"auto\">SW External Emergency Stop<\/span><\/b><span data-contrast=\"auto\"> function.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The <\/span><b><span data-contrast=\"auto\">SW External Emergency Stop<\/span><\/b><span data-contrast=\"auto\"> signal provides the external emergency stop function within the system software. The close circuit state enables operation, while the open circuit state triggers an emergency stop.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:279}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Configuration of the emergency stop status output<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:160,&quot;335559739&quot;:80,&quot;335559740&quot;:279}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">\u00a0Functions can also be assigned to output signals. To the output, a function informing the controller that the robot\u2019s motors have been stopped will be assigned. This can be used as a status signal in the Safety PLC.<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:279}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">In the LogicOP Result No. field, enter: 2.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Then configure the second logical operation:<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><strong>OP: <\/strong>Thru<br \/>\n<strong> IN1: <\/strong>Motor Power Shutoff Command Performed 1 (2001)<br \/>\n<strong> Assign: <\/strong>User Safety Output 1<\/p>\n<figure id=\"attachment_1416\" aria-describedby=\"caption-attachment-1416\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-1416\" src=\"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/03-3-1024x588.jpg\" alt=\"\" width=\"1024\" height=\"588\" srcset=\"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/03-3-1024x588.jpg 1024w, https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/03-3-300x172.jpg 300w, https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/03-3-768x441.jpg 768w, https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/03-3.jpg 1075w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption id=\"caption-attachment-1416\" class=\"wp-caption-text\">Fig. 3. Configuring the status output assignment.<\/figcaption><\/figure>\n<p><span data-contrast=\"auto\">In this configuration, the state of the Motor Power Shutoff Command Performed 1 (2001) signal is transferred to User Safety Output 1.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">This output can be used to transmit information about the safety system status to an external device, such as a Safety PLC. Signal 2001 uses the following logic: the ON state indicates that the motor power shutoff command has not been executed, while the OFF state indicates that the command has been executed.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Updating the Settings<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">After configuring the individual parameters, select Update.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The Update function applies to the parameter changes in the configuration application but does not save them to the CoreCubic-S system. An additional write operation is required to transfer the configuration to the safety system.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Writing the Configuration to CoreCubic-S<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">Go to menu:<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><b><span data-contrast=\"auto\">CoreCubic-S \u2192 Write CoreCubic-S<\/span><\/b><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335559738&quot;:210,&quot;335559739&quot;:210,&quot;335559740&quot;:300}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Enter the user password.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The <\/span><b><span data-contrast=\"auto\">Write CoreCubic-S<\/span><\/b><span data-contrast=\"auto\"> function saves the configured parameters to the CoreCubic-S system.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Once the write process has started, do not close the application until a message confirming its successful completion is displayed.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<h3 aria-level=\"3\"><span data-contrast=\"none\">Restarting the Controller<\/span><span data-ccp-props=\"{&quot;134245418&quot;:true,&quot;134245529&quot;:true,&quot;335559738&quot;:160,&quot;335559739&quot;:80}\">\u00a0<\/span><\/h3>\n<p><span data-contrast=\"auto\">After the parameters have been written successfully, reboot the robot controller..<\/span><span data-ccp-props=\"{&quot;134233117&quot;:false,&quot;134233118&quot;:false,&quot;201341983&quot;:0,&quot;335551550&quot;:1,&quot;335551620&quot;:1,&quot;335559685&quot;:0,&quot;335559737&quot;:0,&quot;335559738&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:279}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">A controller restart is required for the new safety parameters to take effect in the CoreCubic-S system. If the controller is not restarted, a message may be displayed indicating that the safety parameters have been changed and that a power cycle is required.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">After restarting the controller, verify the correct operation of the external E-STOP signal and the status output.<\/span><span data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>E-STOP (emergency stop) is one of the fundamental safety functions used in industrial robotic cells. It enables the robot or other devices within the system to be stopped in an emergency, for example, when an external emergency stop button is pressed. <\/p>\n","protected":false},"author":19,"featured_media":1415,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[17],"tags":[],"class_list":["post-1413","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\r\n<title>Configuring an External E-STOP Signal in CoreCubic-S - ASTOR EN<\/title>\r\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\r\n<link rel=\"canonical\" href=\"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/\" \/>\r\n<meta property=\"og:locale\" content=\"en_GB\" \/>\r\n<meta property=\"og:type\" content=\"article\" \/>\r\n<meta property=\"og:title\" content=\"Configuring an External E-STOP Signal in CoreCubic-S - ASTOR EN\" \/>\r\n<meta property=\"og:description\" content=\"E-STOP (emergency stop) is one of the fundamental safety functions used in industrial robotic cells. It enables the robot or other devices within the system to be stopped in an emergency, for example, when an external emergency stop button is pressed.\" \/>\r\n<meta property=\"og:url\" content=\"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/\" \/>\r\n<meta property=\"og:site_name\" content=\"ASTOR EN\" \/>\r\n<meta property=\"article:published_time\" content=\"2026-11-10T10:20:51+00:00\" \/>\r\n<meta property=\"og:image\" content=\"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head.jpg\" \/>\r\n\t<meta property=\"og:image:width\" content=\"900\" \/>\r\n\t<meta property=\"og:image:height\" content=\"400\" \/>\r\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\r\n<meta name=\"author\" content=\"Konrad Sendrowicz\" \/>\r\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\r\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Konrad Sendrowicz\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\r\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/\"},\"author\":{\"name\":\"Konrad Sendrowicz\",\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/#\\\/schema\\\/person\\\/26a5cf52d352345087b65d82af38901c\"},\"headline\":\"Configuring an External E-STOP Signal in CoreCubic-S\",\"datePublished\":\"2026-11-10T10:20:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/\"},\"wordCount\":706,\"image\":{\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/estop-cubic-head.jpg\",\"articleSection\":[\"Articles\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/\",\"url\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/\",\"name\":\"Configuring an External E-STOP Signal in CoreCubic-S - ASTOR EN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/estop-cubic-head.jpg\",\"datePublished\":\"2026-11-10T10:20:51+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/#\\\/schema\\\/person\\\/26a5cf52d352345087b65d82af38901c\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/estop-cubic-head.jpg\",\"contentUrl\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/estop-cubic-head.jpg\",\"width\":900,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/configuring-an-external-e-stop-signal-in-corecubic-s\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/articles\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Configuring an External E-STOP Signal in CoreCubic-S\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/\",\"name\":\"ASTOR EN\",\"description\":\"technology meets people\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/#\\\/schema\\\/person\\\/26a5cf52d352345087b65d82af38901c\",\"name\":\"Konrad Sendrowicz\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/cropped-LEH_64641200-Srednie-96x96.jpg\",\"url\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/cropped-LEH_64641200-Srednie-96x96.jpg\",\"contentUrl\":\"https:\\\/\\\/www.astor.com.pl\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/06\\\/cropped-LEH_64641200-Srednie-96x96.jpg\",\"caption\":\"Konrad Sendrowicz\"}}]}<\/script>\r\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Configuring an External E-STOP Signal in CoreCubic-S - ASTOR EN","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/","og_locale":"en_GB","og_type":"article","og_title":"Configuring an External E-STOP Signal in CoreCubic-S - ASTOR EN","og_description":"E-STOP (emergency stop) is one of the fundamental safety functions used in industrial robotic cells. It enables the robot or other devices within the system to be stopped in an emergency, for example, when an external emergency stop button is pressed.","og_url":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/","og_site_name":"ASTOR EN","article_published_time":"2026-11-10T10:20:51+00:00","og_image":[{"width":900,"height":400,"url":"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head.jpg","type":"image\/jpeg"}],"author":"Konrad Sendrowicz","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Konrad Sendrowicz","Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/#article","isPartOf":{"@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/"},"author":{"name":"Konrad Sendrowicz","@id":"https:\/\/www.astor.com.pl\/en\/#\/schema\/person\/26a5cf52d352345087b65d82af38901c"},"headline":"Configuring an External E-STOP Signal in CoreCubic-S","datePublished":"2026-11-10T10:20:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/"},"wordCount":706,"image":{"@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/#primaryimage"},"thumbnailUrl":"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head.jpg","articleSection":["Articles"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/","url":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/","name":"Configuring an External E-STOP Signal in CoreCubic-S - ASTOR EN","isPartOf":{"@id":"https:\/\/www.astor.com.pl\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/#primaryimage"},"image":{"@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/#primaryimage"},"thumbnailUrl":"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head.jpg","datePublished":"2026-11-10T10:20:51+00:00","author":{"@id":"https:\/\/www.astor.com.pl\/en\/#\/schema\/person\/26a5cf52d352345087b65d82af38901c"},"breadcrumb":{"@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/#primaryimage","url":"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head.jpg","contentUrl":"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2026\/11\/estop-cubic-head.jpg","width":900,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/www.astor.com.pl\/en\/articles\/configuring-an-external-e-stop-signal-in-corecubic-s\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.astor.com.pl\/en\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/www.astor.com.pl\/en\/articles\/"},{"@type":"ListItem","position":3,"name":"Configuring an External E-STOP Signal in CoreCubic-S"}]},{"@type":"WebSite","@id":"https:\/\/www.astor.com.pl\/en\/#website","url":"https:\/\/www.astor.com.pl\/en\/","name":"ASTOR EN","description":"technology meets people","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.astor.com.pl\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.astor.com.pl\/en\/#\/schema\/person\/26a5cf52d352345087b65d82af38901c","name":"Konrad Sendrowicz","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2025\/06\/cropped-LEH_64641200-Srednie-96x96.jpg","url":"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2025\/06\/cropped-LEH_64641200-Srednie-96x96.jpg","contentUrl":"https:\/\/www.astor.com.pl\/en\/wp-content\/uploads\/2025\/06\/cropped-LEH_64641200-Srednie-96x96.jpg","caption":"Konrad Sendrowicz"}}]}},"_links":{"self":[{"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/posts\/1413","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/comments?post=1413"}],"version-history":[{"count":3,"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/posts\/1413\/revisions"}],"predecessor-version":[{"id":1420,"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/posts\/1413\/revisions\/1420"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/media\/1415"}],"wp:attachment":[{"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/media?parent=1413"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/categories?post=1413"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.astor.com.pl\/en\/wp-json\/wp\/v2\/tags?post=1413"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}